24502 – ACIC 600V, 4 Pr #16 Str TC, PVC Ins E1, IS/OS, PVC Jkt, AIA Armor, PVC Jkt, 105C Dry 75C Wet CSA HLABCD SUN RES -40C

Call for Price

Compare

Description

Product Overview

Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Pair(s) 4 16 AWG 7×24 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PVC – Polyvinyl Chloride 0.03 in (0.76 mm) 0.118 in (3.00 mm) ICEA Chart E1
Inner Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 18 AWG (7×26) TC
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 16 AWG (7×24) TC
Inner Jacket
Material Nom. Thickness Nom. Diameter Ripcord Color
PVC – Polyvinyl Chloride 0.063 in (1.6 mm) 0.673 in (17.1 mm) Yes Black
Armor
Armor Type & Material Armor Thickness Diameter Over Armor
AIA – Aluminum Interlock Armor 0.025 in (0.64 mm) 0.893 in (22.7 mm)
Outer Jacket
Separator Material Nom. Thickness Nom. Diameter Ripcord
Polyester Tape PVC – Polyvinyl Chloride 0.052 in (1.3 mm) 0.997 in Yes
Overall Cable Diameter (Nominal): 0.997 in

Electrical Characteristics

Electricals
Nom. Conductor DCR Nom. Inner Shield DCR Max. Current
4.2 Ohm/1000ft 5.4 Ohm/1000ft (18 Ohm/km) 4.4 Amps per Conductor at 30ºC
Voltage
Voltage Rating
600 V

Mechanical Characteristics

Temperature
Operating Installation
Dry: -40°C to +105°C, Wet: -40°C to +75°C -25°C To +105
Bend Radius
Stationary Min. Installation Min.
11.96 in (303.8 mm) 11.96 in
Max. Pull Tension: 200 lbs (91 kg)
Bulk Cable Weight: 412 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance
AWM Compliance: C22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31 Low Acid Test
CEC / C(UL) Compliance: ACIC, HLABCD, ACIC
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)

History

Update and Revision: Revision Number: 0.375 Revision Date: 01-04-2024

Part Numbers

Variants
Item # Putup Type UPC
24502 0602500 Reel 612825324300
24502 0605000 Reel 612825324317
24502 0605000 Reel 612825324317
24502 01010000 Reel
24502 06010000 Reel