Description
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 2 | 18 AWG | 42×34 | BC – Bare Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | PVC – Polyvinyl Chloride | 0.032 in (0.81 mm) | 0.110 in (2.79 mm) | Blue, Brown |
Outer Shield
Material |
---|
No Shield |
Outer Jacket
Separator | Material | Nom. Thickness | Nom. Diameter |
---|---|---|---|
Paper Tape | PVC – Polyvinyl Chloride | 0.035 in (0.89 mm) | 0.29 in |
Overall Cable Diameter (Nominal): | 0.29 in |
Electrical Characteristics
Electricals
Nom. Conductor DCR | Max. Current |
---|---|
6.97 Ohm/1000ft | 10 Amps per Conductor at 25ºC (7 Amps over 50 ft) |
Voltage
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
105°C Dry, 60°C Wet | -35°C To +60°C Wet/105°C Dry |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
2.9 in (74 mm) | 2.9 in |
Max. Pull Tension: | 41 lbs (19 kg) |
Bulk Cable Weight: | 38 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor, Outdoor, Sunlight Resistance, Oil Resistance |
Flammability / Reaction to Fire: | VW-1 |
NEC / UL Compliance: | Article 400, SJTOW |
AWM Compliance: | SJTOW |
CEC / C(UL) Compliance: | LL7874 |
European Directive Compliance: | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Product Notes
Notes: | Jacket is Oil Resistant |
History
Update and Revision: | Revision Number: 0.393 Revision Date: 02-15-2024 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
19506 B59250 | Black, Matte | Reel | 250 ft | 612825127147 | C |