Description
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 2 | 16 AWG | 65×34 | BC – Bare Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | EPDM – Ethylene Propylene Diene Monomer | 0.033 in (0.84 mm) | 0.123 in (3.12 mm) | Black, White |
Outer Shield
Material |
---|
No Shield |
Outer Jacket
Separator | Material | Nom. Thickness | Nom. Diameter |
---|---|---|---|
Cotton Serve | CPE – Chlorinated Polyethylene (Thermoset) | 0.065 in (1.7 mm) | 0.385 in |
Overall Cable Diameter (Nominal): | 0.385 in |
Electrical Characteristics
Electricals
Nom. Conductor DCR | Max. Current |
---|---|
4.4 Ohm/1000ft | 13 Amps per Conductor at 25ºC (10 Amps over 50 ft) |
Voltage
UL Voltage Rating |
---|
600 V |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
90°C | -20°C To +90°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
3.85 in (97.8 mm) | 3.85 in |
Max. Pull Tension: | 65 lbs (29 kg) |
Bulk Cable Weight: | 76 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor, Oil Resistance |
NEC / UL Compliance: | Article 400, SO |
AWM Compliance: | SO |
CEC / C(UL) Compliance: | LL7874 |
European Directive Compliance: | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Product Notes
Notes: | Oil Resistant Jacket; Overall Cabling Separator Material: Cotton Serve |
History
Update and Revision: | Revision Number: 0.394 Revision Date: 02-15-2024 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | UPC | Footnote |
---|---|---|---|---|---|
19203 010250 | Black | Reel | 250 ft | 612825126751 | F |