Description
Product Overview
Suitable Applications: | Digital Video, 6 Gb/s UHDTV, HD-SDI 1080p |
Construction Details
RG Type: | Mini 59 |
Conductor
Size | Stranding | Nom. Diameter | Material |
---|---|---|---|
23 AWG | Solid | 0.023 in | BC – Bare Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|---|---|
FEP – Fluorinated Ethylene Propylene (Foam) | 0.102 in (2.59 mm) | White |
Outer Shield
Layer | Outer Shield Type | Material | Material Trade Name | Coverage |
---|---|---|---|---|
1 | Tape | Tri-Laminate (Alum+Poly+Alum) | Duofoil® | 100% |
2 | Braid | Tinned Copper (TC) | 95% |
Outer Jacket
Material | Nom. Diameter |
---|---|
PVC – Polyvinyl Chloride | 0.159 in (4.04 mm) |
Overall Cable Diameter (Nominal): | 0.159 in (4.04 mm) |
Electrical Characteristics
Return Loss (RL)
Frequency | Min. Return Loss |
---|---|
5 – 1600 MHz | 23 dB |
1600 – 4500 MHz | 21 dB |
4500 – 6000 MHz | 15 dB |
Attenuation
Frequency | Nom. Attenuation |
---|---|
1 MHz | 0.38 dB/100ft |
3.58 MHz | 0.76 dB/100ft |
10 MHz | 1.3 dB/100ft |
71.5 MHz | 3.1 dB/100ft |
135 MHz | 4.1 dB/100ft |
270 MHz | 5.8 dB/100ft |
360 MHz | 6.9 dB/100ft |
540 MHz | 8.7 dB/100ft |
720 MHz | 10.3 dB/100ft |
750 MHz | 10.5 dB/100ft |
1000 MHz | 12.4 dB/100ft |
1500 MHz | 15.7 dB/100ft |
2250 MHz | 19.9 dB/100ft |
3000 MHz | 23.8 dB/100ft |
4500 MHz | 30.3 dB/100ft |
6000 MHz | 36.4 dB/100ft |
Electricals
Nom. Conductor DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
---|---|---|---|---|
20.1 Ohm/1000ft | 3.7 Ohm/1000ft (12 Ohm/km) | 16.6 pF/ft (54.5 pF/m) | 75 Ohm | 80% |
Voltage
UL Voltage Rating |
---|
300 V (CMP) |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
75°C | 0°C to +75°C |
Bend Radius
Installation Min. |
---|
4 in (100 mm) |
Max. Pull Tension: | 40 lbs (18 kg) |
Bulk Cable Weight: | 21 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor – Plenum, Indoor |
Sustainability: | CA Prop 65 |
Flammability / Reaction to Fire: | NFPA 262 |
CPR Compliance: | CPR Euroclass: Eca; CPR UKCA Class: Eca |
NEC / UL Compliance: | CMP |
CEC / C(UL) Compliance: | CMP |
European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
UK Regulation Compliance: | UKCA Mark |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Non-Plenum Number: | 1855A |
History
Update and Revision: | Revision Number: 0.515 Revision Date: 04-24-2023 |
Part Numbers
Variants
Item # | Color | Putup Type | Length | UPC |
---|---|---|---|---|
1855P 0101000 | Black | Reel | 1,000 ft | 612825124771 |
1855P 0061000 | Blue, Light | Reel | 1,000 ft | 612825124740 |
1855P 0011000 | Brown | Reel | 1,000 ft | 612825124702 |
1855P 0081000 | Gray | Reel | 1,000 ft | 612825124764 |
1855P N3U1000 | Green, Mil | Reel | 1,000 ft | 612825124696 |
1855P 8771000 | Natural | Reel | 1,000 ft | 612825124788 |
1855P 0031000 | Orange | Reel | 1,000 ft | 612825124726 |
1855P 0021000 | Red | Reel | 1,000 ft | 612825124719 |
1855P 0071000 | Violet | Reel | 1,000 ft | 612825124757 |
1855P 0041000 | Yellow | Reel | 1,000 ft | 612825124733 |