Product Overview
| Suitable Applications: |
Multi-Media Control, RS-422, RS–232, 60754-1, 60754-2, 61034, Limited Smoke, IEC 60332-1-2, Cca |
Physical Characteristics (Overall)
| Element |
AWG |
Stranding |
Material |
No. of Conductors |
No. of Pairs |
| 22 AWG |
22 |
7×30 |
TC – Tinned Copper |
|
1 |
| 18 AWG |
18 |
16×30 |
TC – Tinned Copper |
2 |
|
| Element |
Material |
Material Trade Name |
Nominal Diameter |
| 18 AWG |
PE – Polyethylene (Foam) |
Datalene® |
2.0 mm |
| 22 AWG |
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
|
1.74 mm |
| Number |
Color |
| 1 |
Blue & White |
| 2 |
Red & Black |
| Type |
Layer |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire Diameter |
Drainwire AWG |
Drainwire Construction n x D |
| Tape |
22 AWG Pair |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
TC – Tinned Copper |
0.6 mm |
24 |
|
|
|
|
|
|
|
|
|
7×32 |
| Material |
Nominal Diameter |
Nominal Wall Thickness |
Ripcord |
| LSZH – Low Smoke Zero Halogen (Flame Retardant) |
7.9 mm |
1.15 mm |
Yes |
Electrical Characteristics
| Element |
Nominal Conductor DCR |
Nominal Conductor DCR Conductor Resistance |
| 22 AWG |
53.5 Ohm/km |
53.5 Ohm/km |
| 18 AWG |
22.6 Ohm/km |
22.6 Ohm/km |
| Element |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
| 22 AWG Pair(s) |
46 pF/m |
125 pF/m |
| 22 AWG Pair(s) |
|
|
| Element |
Nominal Inductance |
| 22 AWG |
0.76 µH/m |
| 18 AWG |
0.55 µH/m |
| Nominal Balanced Characteristic Impedance Description |
Nominal Characteristic Impedance |
Nominal Characteristic Impedance Description |
| 22 AWG Pair |
100 Ohm |
22 AWG Pair |
| Max. Recommended Current [A] |
| 3.8 Amps per Conductor at 25ºC (22 AWG) |
Temperature Range
| Operating Temperature Range: |
-30°C To +80°C |
Mechanical Characteristics
| Min. Bend Radius/Minor Axis: |
65 mm |
Standards
| CPR Euroclass: |
Cca-s1,d1,a1 |
Applicable Environmental and Other Programs
| Environmental Space: |
Indoor – Euroclass Cca |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| EU Directive 2011/65/EU (RoHS 2): |
Yes |
| EU Directive 2012/19/EU (WEEE): |
Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
| EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
Suitability
| Suitability – Indoor: |
Yes |
| Suitability – Non-Halogenated: |
Yes |
| Suitability – Outdoor: |
Yes |
| Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: |
IEC 60332-1-2 |
| IEC 60754-1 – Halogen Amount: |
Zero |
| IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: |
2.5 µS/mm |
| IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: |
4.3 |
Plenum/Non-Plenum
History
| Update and Revision: |