1360A – Fieldbus, 1 Pr #16 Str TC, PP Ins, OS, PVC Jkt, PLTC-ER, ITC-ER, c(UL)CMG

Call for Price

Description

Product Overview

Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Pair(s) 1 16 AWG 7×24 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PP – Polypropylene 0.029 in (0.74 mm) 0.117 in (2.97 mm) Blue & Orange
Outer Shield
Shield Type Material Coverage Drainwire Type Notes
Tape Bi-Laminate (Alum+Poly) 100% 20 AWG (7×28) TC Foil In – with polyester wrap
Outer Jacket
Material Nom. Thickness Nom. Diameter Ripcord
PVC – Polyvinyl Chloride 0.065 in (1.7 mm) 0.40 in (10 mm) Yes
Overall Cable Diameter (Nominal): 0.40 in (10 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Max. Capacitance Unbalance Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Pair(s) 5.9 Ohm/1000ft 1.2 pF/ft (3.9 pF/m) 45 pF/ft 100 Ohm 66% 8 Amps per Conductor at 25ºC
Nom. Outer Shield DCR: 7.5 Ohm/1000ft (25 Ohm/km)
High Frequency (Nominal/Typical)
Element Frequency [MHz] Nom. Insertion Loss (Attenuation)
Pair(s) 0.039 0.08 dB/100ft
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted) [Ohm]
0.031 0.091 dB/100ft 100
Voltage
UL Voltage Rating
300 V (CMG, PLTC-ER), 150 V (ITC-ER)

Mechanical Characteristics

Temperature
UL Temperature Operating
105°C -40°C to +105°C
Bend Radius
Stationary Min. Installation Min.
4 in (100 mm) 4 in (100 mm)
Max. Pull Tension: 84 lbs (38 kg)
Bulk Cable Weight: 69 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Burial
Flammability / Reaction to Fire: UL 1685 UL Loading, FT4, IEEE 1202, IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca
NEC / UL Compliance: Article 725, Article 727, Article 800, CM
CEC / C(UL) Compliance: CMG
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance: UKCA Mark
APAC Compliance: China RoHS II (GB/T 26572-2011)

Product Notes

Notes: Fieldbus: Orange jacket. Profibus PA: Intrinsically Safe Blue jacket.

History

Update and Revision: Revision Number: 0.510 Revision Date: 02-15-2024

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
1360A 0031000 Orange Reel 1,000 ft 612825112631 C