1335A – Fieldbus, 2 C #16 Str TC, PO Ins, OS+TC Brd, PVC Jkt, CM

Call for Price

Compare

Description

Product Overview

Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor
AWG Stranding Material No. of Pairs
16 7×24 TC – Tinned Copper 1
Conductor Count: 2
Insulation
Material
PP – Polypropylene
Color Chart
Number Color
1 Blue & Orange
Outer Shield
Type Layer Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D
Tape 1 Bi-Laminate (Alum+Poly) Beldfoil® 100% TC – Tinned Copper 20 7×28
Braid 2 Tinned Copper (TC) 65%
Outer Jacket
Material Nominal Diameter Ripcord
PVC – Polyvinyl Chloride 0.34 in Yes

Electrical Characteristics

Conductor DCR
Max. Outer Shield DCR Nominal Conductor DCR
4.9 Ohm/1000ft 4.2 Ohm/1000ft
Capacitance
Max. Capacitance Unbalance Nom. Capacitance Conductor to Shield Nom.Mutual Capacitance
1.2 pF/ft 45 pF/ft 24 pF/ft
Impedance
Nominal Characteristic Impedance
100 Ohm
High Frequency (Nominal/Typical)
Nom. Insertion Loss
0.066 dB/100ft
Delay
Nominal Velocity of Propagation (VP) [%]
66%
High Frequency
Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted)
0.091 dB/100ft 100 Ohm
Current
Element Max. Recommended Current [A]
Per Conductor 8 Amps per Conductor
Voltage
UL Voltage Rating
300 V RMS
Electrical Characteristics Notes: Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft
Other Electrical Characteristic 2: 31.25 KBits/sec

Temperature Range

UL Temp Rating: 90°C
Operating Temperature Range: -30°C to +90°C

Mechanical Characteristics

Oil Resistance: Yes
UV Resistance: Yes
Bulk Cable Weight: 79 lbs
Max. Pull Tension: 84 lbs
Min. Bend Radius/Minor Axis: 3.4 in

Standards

NEC Articles: Article 725, Article 727, Article 800
NEC/(UL) Compliance: CM, ITC, PLTC
CEC/C(UL) Compliance: CM
CPR Euroclass: Eca

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Burial: Yes – UL
Suitability – Indoor: Yes
Suitability – Oil Resistance: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 UL Loading
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color Put-Up Type Length UPC
1335A 0061000 Blue, Light Reel 1,000 ft 612825112198
1335A 0031000 Orange Reel 1,000 ft 612825112167
Footnote: C – CRATE REEL PUT-UP.

History

Update and Revision: Revision Number: 0.507 Revision Date: 08-07-2023