Product Overview
Suitable Applications: |
outdoor, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force, |
Physical Characteristics (Overall)
Element |
AWG |
Stranding |
Material |
No. of Pairs |
Pair(s) |
24 |
7×32 |
BC – Bare Copper |
4 |
Color |
White/Blue Stripe & Blue |
White/Orange Stripe & Orange |
White/Green Stripe & Green |
White/Brown Stripe & Brown |
Material |
Nominal Diameter |
Ripcord |
PVC – Polyvinyl Chloride |
0.295 in |
Yes |
Type |
Material |
Material Trade Name |
Coverage [%] |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
Material |
Nominal Diameter |
Ripcord |
Separator Material |
PVC – Polyvinyl Chloride |
0.610 in |
No |
Polyester Tape |
Construction and Dimensions
Diameter over Armoring |
0.518 in |
Electrical Characteristics
Max. Conductor DCR |
93.8 Ohm/km |
Max. Capacitance Unbalance |
330 pF/100m |
Frequency [MHz] |
Max. Insertion Loss (Attenuation) |
Min. NEXT [dB] |
Min. PSNEXT [dB] |
Min. ACR [dB] |
Min. PSACR [dB] |
Min. ACRF (ELFEXT) [dB] |
Min. PSACRF (PSELFEXT) [dB] |
Min. RL (Return Loss) [dB] |
Min. SRL (Structural Return Loss) |
Max./Min. Input Impedance (unFitted) |
Max./Min. Fitted Impedance |
1 MHz |
2.0 dB/100m |
65.3 dB |
62.3 dB |
62.8 dB |
60 dB |
63.8 dB |
60.8 dB |
20 dB |
23 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
4 MHz |
4.9 dB/100m |
56.3 dB |
53.3 dB |
51.4 dB |
48.4 dB |
51.7 dB |
48.7 dB |
23 dB |
23 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
8 MHz |
6.9 dB/100m |
51.8 dB |
48.8 dB |
44.9 dB |
41.9 dB |
45.7 dB |
42.7 dB |
24.5 dB |
24.5 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
10 MHz |
7.8 dB/100m |
50.3 dB |
47.3 dB |
42.5 dB |
39.5 dB |
43.8 dB |
40.8 dB |
25 dB |
25 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
16 MHz |
9.9 dB/100m |
47.3 dB |
44.3 dB |
37.4 dB |
34.4 dB |
39.7 dB |
36.7 dB |
25 dB |
25 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
20 MHz |
11.1 dB/100m |
45.8 dB |
42.8 dB |
34.7 dB |
31.7 dB |
37.7 dB |
34.7 dB |
25 dB |
25 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
25 MHz |
12.5 dB/100m |
44.3 dB |
41.3 dB |
21.8 dB |
28.8 dB |
35.8 dB |
32.8 dB |
24.3 dB |
24.3 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
31.25 MHz |
14.1 dB/100m |
42.9 dB |
39.9 dB |
28.8 dB |
25.8 dB |
33.9 dB |
30.9 dB |
23.6 dB |
23.6 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
62.5 MHz |
20.4 dB/100m |
38.4 dB |
35.4 dB |
18 dB |
15 dB |
27.8 dB |
24.8 dB |
21.5 dB |
21.5 dB |
100 ± 15 Ohm |
100 ± 15 Ohm |
100 MHz |
26.4 dB/100m |
35.3 dB |
32.3 dB |
8.9 dB |
5.9 dB |
23.8 dB |
20.8 dB |
20.1 dB |
20.1 dB |
100 ± 15 Ohm |
|
Max. Recommended Current [A] |
15 pF/ft |
UL Description |
UL Voltage Rating |
CM |
300 V |
Temperature Range
Storage Temperature Range: |
-40°C to +85°C |
Operating Temperature Range: |
-40°C To +75°C |
Mechanical Characteristics
Bulk Cable Weight: |
139 lbs/1000ft |
Max. Pull Tension: |
100 lbs |
Standards
NEC Articles: |
Article 800 |
CEC/C(UL) Compliance: |
CMG, HL |
ISO/IEC Compliance: |
ISO/IEC 11801-1, IEC 61156-5 |
Data Category: |
Category 5e |
TIA/EIA Compliance: |
ANSI/TIA-568.2-D Category 5e |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor/Outdoor |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
EU REACH SVHC Compliance (yyyy-mm-dd): |
2020-01-16 |
MII Order #39 (China RoHS): |
Yes |
Suitability
Suitability – Indoor: |
Yes |
Suitability – Non-Halogenated: |
No |
Suitability – Oil Resistance: |
Yes |
Suitability – Outdoor: |
Yes |
Suitability – Sunlight Resistance: |
Yes |
Flammability, LS0H, Toxicity Testing
CSA/C(UL) Flammability: |
FT4 |
UL Flammability: |
UL 1685 (UL Loading) |
Product Notes
Notes: |
Operating temperatures are subject to length de-rating |
History
Update and Revision: |
Revision Number: 0.33 Revision Date: 10-11-2023 |