1012A – Type KX Thermocouple, 4 Pr #20+22 Sol, PVC Ins Yel, Red, IS/OS, Yellow PVC Jkt, 300V PLTC ITC CMG

Call for Price

Compare

Description

Product Overview

Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, …),Thermocouple, distributed control system (DCS),programmable logic controller (PLC)

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Pair(s) 4 20 AWG Solid Chromel & Alumel
Comm 1 22 AWG 7×30 BC – Bare Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PVC – Polyvinyl Chloride 0.021 in (0.53 mm) 0.074 in (1.9 mm) Yellow and Red Numbered 1, Yellow and Red Numbered 2, Yellow and Red Numbered 3, Yellow and Red Numbered 4
Comm PVC – Polyvinyl Chloride 0.019 in (0.48 mm) 0.066 in (1.7 mm) Orange
Inner Shield
Shield Type Material Coverage Drainwire Type Notes
Tape Bi-Laminate (Alum+Poly) 100% 22 AWG (7×30) TC Polyster Flim
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 20 AWG (7×28) TC
Outer Jacket
Separator Material Nom. Thickness Nom. Diameter Ripcord
Polyester Tape PVC – Polyvinyl Chloride 0.053 in (1.3 mm) 0.447 in Yes
Overall Cable Diameter (Nominal): 0.447 in

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Inner Shield DCR Max. Current
Chromel 420 Ohm/1000ft 12.3 Ohm/1000ft (40.4 Ohm/km) 2.8 Amps per Conductor at 30ºC
Alumel 161 Ohm/1000ft (528 Ohm/km) 2.8 Amps per Conductor at 30ºC
Comm 18.5 Ohm/1000ft (60.7 Ohm/km) 4.8 Amps per Conductor at 30ºC
Voltage
UL Voltage Rating
300 V

Mechanical Characteristics

Temperature
UL Temperature Operating
UL: 105°C, AWM 2464: 80°C -20°C To +105°C
Bend Radius
Stationary Min. Installation Min.
4.47 in (114 mm) 4.47 in
Max. Pull Tension: 635 lbs (288 kg)
Bulk Cable Weight: 83 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, UV Resistance, Burial
Flammability / Reaction to Fire: UL1685 FT4 Loading, FT4, IEEE 1202 FT4
NEC / UL Compliance: Article 725, Article 727, Article 800
AWM Compliance: AWM 2464
CEC / C(UL) Compliance: CMG
European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)

Product Notes

Notes: Chromel & Alumel = “”Chromel and Alumel are Hoskins Manufacturing Company trademarks.””

History

Update and Revision: Revision Number: 0.434 Revision Date: 01-10-2024

Part Numbers

Variants
Item # Color Putup Type Length UPC Footnote
1012A 0045000 Yellow Reel 5,000 ft 612825102687 C Z