RTO7P0.75P – RailTuff™ Thin wall cable EN 50306-4 7P 300V 7Pr 0.75mm² Str TC, XLPO Ins, TCBS, XLPO Outer Jkt

Call for Price

Compare

Description

Product Overview

Suitable Applications: Applicable for fixed or moderate flexing wiring inside Railway Rolling Stock like High-Speed Trains (CRH, Shinkansen, ICE, TGV), Metro,
locomotives, and trolley buses, etc

Construction Details

Conductor
Size Stranding Material
0.75 mm² 37×0.16 mm TC – Tinned Copper
Insulation
Material Nom. Thickness Nom. Insulation Diameter Color Code Notes
XLP, XLPO, XLPE 0.27 mm (0.011 in) 1.62 mm (0.0638 in) White#1, White#2, White#3, White#4, White#5, White#6, White#7, White#8, White#9, White#10, White#11, White#12, White#13, White#14 D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Table Notes: D.C. stability on insulation at 300Vdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown
Outer Shield
Shield Type Material Coverage
Braid Tinned Copper (TC) 80%
Outer Jacket
Material Nom. Thickness Nom. Diameter
XLP, XLPO, XLPE 1.30 mm (0.0512 in) 11.10 mm (0.4370 in)
Overall Cable Diameter (Nominal): 11.1 ± 0.30 mm

Electrical Characteristics

Electricals
Max. Conductor DCR
26.7 Ohm/km (8.14 Ohm/1000ft)
Voltage
Breakdown Voltage
2.5kVac/5min

Mechanical Characteristics

Temperature
Operating
-40°C to +120°C
Bend Radius
Stationary Min. Installation Min.
111 mm (4.37 in) 111 mm (4.37 in)
Bulk Cable Weight: 204.4 kg/km (137.4 lbs/1000ft)

Standards and Compliance

Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-2-25
ISO/IEC Compliance: IEC 60228
CENELEC Compliance: EN 50306-4EN 45545-2
European Halogen Free Standards: IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 10 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
Other Standard Compliance(s): TJ/CL 313

Product Notes

Notes: EMEA PN: RTO7P075P; Table 7 Category MM, ROHS Compliant

History

Update and Revision: Revision Number: 0.58 Revision Date: 11-27-2023