H125A07 – H125A07 – Broadband Coax, H125CH, 18 AWG Solid BC, Foil + 65% TC Braid, LSZH Jkt

Call for Price

Description

Product Overview

Suitable Applications: Broadband, Cable Television (CATV), RF drop cable, Over-The-Air (OTA) antennas

Construction Details

RG Type: 6
Conductor
No. of Elements Size Stranding Nom. Diameter Material
1 18 AWG Solid 1 mm BC – Bare Copper
Insulation
Element Material Nom. Insulation Diameter
Insulated Conductor PE – Polyethylene (Foam) 4.8 mm (0.19 in)
Outer Shield
Layer Outer Shield Type Material Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) 100%
2 Braid Tinned Copper (TC) 63%
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 6.8 mm
Table Notes: According to EN 50290-2-20

Electrical Characteristics

Regularity of Impedance: Min. 40 dB
Return Loss (RL)
Frequency Min. Return Loss
5 – 470 MHz 23 dB
470 – 1000 MHz 20 dB
1000 – 2000 MHz 18 dB
2000-3000 MHz 16 dB
Table Notes: In each frequency band, 3 peak values up to 4 dB lower are allowed
Attenuation
Frequency Nom. Attenuation
5 MHz 1.8 dB/100m
50 MHz 4.7 dB/100m
100 MHz 6.5 dB/100m
200 MHz 9.1 dB/100m
230 MHz 9.8 dB/100m
400 MHz 12.9 dB/100m
600 MHz 16 dB/100m
800 MHz 18.6 dB/100m
862 MHz 19.3 dB/100m
1000 MHz 20.9 dB/100m
1350 MHz 24.6 dB/100m
1750 MHz 28.4 dB/100m
2400 MHz 34 dB/100m
3000 MHz 38.6 dB/100m
Table Notes: Max. attenuation 10% higher
Electricals
Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
23 Ohm/km (7.0 Ohm/1000ft) 18 Ohm/km (5.5 Ohm/1000ft) 55 pF/m (17 pF/ft) 75 Ohm 81%
Transfer Impedance
Max. Transfer Impedance
15 mOhm/m
Transfer Impedance Class: B
Screening
Frequency Min. Screening Attenuation
100 – 1000 MHz 85 dB
Screening Class: B

Mechanical Characteristics

Temperature
Operating Installation Storage
-30°C To +70°C -5°C To +50°C -30°C To +70°C
Bend Radius
Stationary Min.
35 mm (1.4 in)
Max. Pull Tension: 55 N (12 lbf)

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Eca
Flammability / Reaction to Fire: IEC 60332-1-2
CPR Compliance: CPR Euroclass: Eca
CENELEC Compliance: EN 50117-1EN 50117-9-2EN 50290-2-20
European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark
UK Regulation Compliance: UKCA Mark

History

Update and Revision: Revision Number: 0.215 Revision Date: 03-30-2023