CX4C2 – CX4C2 – Broadband Coax 4, 11 AWG Solid BC, Foil + 60% BC Braid, LSZH Jkt

Call for Price

Compare
SKU: CX4C2 Categories: , , ,

Description

Product Overview

Suitable Applications: Broadband, Cable Television (CATV)

Construction Details

Series Type: CATV-Trunk Type
Conductor
No. of Elements Size Stranding Nom. Diameter Material
1 12 AWG Solid 2.23 mm BC – Bare Copper
Insulation
Element Material Nom. Insulation Diameter
Insulated Conductor PE – Polyethylene (Foam) 10.2 mm (0.402 in)
Table Notes: Centricity min. 85%
Outer Shield
Layer Outer Shield Type Material Coverage
1 Tape Bi-Laminate (Bare Copper+Poly) 100%
2 Braid Bare Copper (BC) 59%
Outer Jacket
Material Nom. Diameter
LSZH – Low Smoke Zero Halogen (Flame Retardant) 13.8 mm
Table Notes: According to European Standard EN 50290-2-20

Electrical Characteristics

Regularity of Impedance: Min. 46 dB
Return Loss (RL)
Frequency Min. Return Loss
5 – 30 MHz 26 dB
30 – 470 MHz 26 dB
470 – 862 MHz 23 dB
862 – 2400 MHz 18 dB
Table Notes: In each frequency band, 3 peak values up to 4 dB lower are allowed
Attenuation
Frequency Nom. Attenuation
5 MHz 0.6 dB/100m
50 MHz 1.9 dB/100m
100 MHz 2.8 dB/100m
200 MHz 4 dB/100m
400 MHz 5.9 dB/100m
600 MHz 7.4 dB/100m
800 MHz 8.8 dB/100m
1000 MHz 10 dB/100m
1350 MHz 11.9 dB/100m
1750 MHz 13.9 dB/100m
2150 MHz 15.7 dB/100m
2400 MHz 16.8 dB/100m
Table Notes: Max. attenuation 10% higher
Electricals
Max. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance
Cond-to-Shield
Nom. Characteristic Impedance Nom. Velocity of Prop.
4.5 Ohm/km (1.4 Ohm/1000ft) 4.5 Ohm/km (1.4 Ohm/1000ft) 54 pF/m (16 pF/ft) 75 Ohm 82%
Transfer Impedance
Max. Transfer Impedance
Max. 2.5 mOhm/m
Typ. 1.9 mOhm/m
Screening
Frequency Min. Screening Attenuation
30 – 1000 MHz 95 dB
Screening Class: A+

Mechanical Characteristics

Temperature
Operating Installation Storage
-25°C To +70°C -5°C To +50°C -25°C To +70°C
Bend Radius
Stationary Min.
150 mm (5.9 in)
Max. Pull Tension: 400 N (90 lbf)
Bulk Cable Weight: 196 kg/km

Standards and Compliance

Environmental Suitability: Indoor – Euroclass Eca
Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-3-24
CPR Compliance: CPR Euroclass: Eca
ISO/IEC Compliance: IEC 61196
CENELEC Compliance: EN 50117-1
European Halogen Free Standards: IEC 62821-1 Halogen Free Compliance = Yes, IEC 60754-1 – Halogen Amount = Zero, IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity = 2.5 µS/mm, IEC 60754-2 – Halogen Acid Gas Amount – Min. pH = 4.3
European Directive Compliance: EU CE Mark
UK Regulation Compliance: UKCA Mark

History

Update and Revision: Revision Number: 0.219 Revision Date: 12-19-2022