Welcome to American Tele Data

USA MADE - BABA COMPLIANT

AMERICAN TELEDATA

855 - 848 - Data

855 - 40 - Fiber

A0214KO – TC-ER VN/PVC, 2+G C #14 Str BC, PVC-NYL Ins, E2, 1 C #14 Str BC Ins Grnd, OS, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR

Call for Price

Description

Product Overview

Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material No. of Conductors
Conductor(s) 14 7×22 BC – Bare Copper 2
Ground 14 7×22 BC – Bare Copper 1
Conductor Count: 2
Insulation
Material Nominal Diameter Nominal Wall Thickness
PVC/Nylon – Polyvinyl Chloride + Nylon 0.116 in 0.024 in
PVC/Nylon – Polyvinyl Chloride + Nylon 0.0116 in 0.024 in
Color Chart
Number Color
1 Black
2 Red
Ground Green
Outer Shield
Type Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG
Tape Bi-Laminate (Alum+Poly) Beldfoil® 100% TC – Tinned Copper 14
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
PVC – Polyvinyl Chloride 0.348 in 0.047 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
2.52 Ohm/1000ft
Current
Max. Recommended Current [A]
25 Amps per Conductor at 30ºC
Voltage
Description UL Description UL Voltage Rating Voltage Rating [V]
Type TC TC 600 V RMS 600 V RMS
NPLF 150 V RMS

Temperature Range

UL Temp Rating: 90°C Wet/Dry
Operating Temperature Range: ‘-30°C To +90°C

Mechanical Characteristics

UV Resistance: Yes
Bulk Cable Weight: 89 lbs/1000ft
Max. Pull Tension: 64 lbs
Min. Bend Radius/Minor Axis: 3.48 in

Standards

NEC Articles: Article 336
NEC/(UL) Compliance: NPLF, TC-ER, THHN/THWN Singles

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: Yes
EU CE Mark: Yes

Suitability

Suitability – Burial: Yes
Suitability – Indoor: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL 1685 UL Loading
IEEE Flammability: 1202
UL voltage rating: 600 V RMS (Type TC)

Plenum/Non-Plenum

Plenum (Y/N): No

History

Update and Revision: Revision Number: 0.52 Revision Date: 01-10-2024