A02141O – TC-ER VN/PVC, 2+G C #14 Str BC, PVC-NYL Ins, E1, 1 C #14 Str BC Ins Grnd, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR

Call for Price

Description

Product Overview

Suitable Applications: harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material No. of Conductors
Conductor(s) 14 7×22 BC – Bare Copper 2
Ground 14 7×22 BC – Bare Copper 1
Conductor Count: 2
Insulation
Material Nominal Diameter Nominal Wall Thickness
PVC/Nylon – Polyvinyl Chloride + Nylon 0.116 in 0.0225 in
PVC/Nylon – Polyvinyl Chloride + Nylon 0.116 in 0.0225 in
Color Chart
Number Color
1 Black
2 White
Ground Green
Outer Jacket
Material Nominal Diameter Nominal Wall Thickness
PVC – Polyvinyl Chloride 0.344 in 0.047 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
2.52 Ohm/1000ft
Current
Max. Recommended Current [A]
25 Amps per Conductor at 30ºC
Voltage
UL Description UL Voltage Rating Voltage Rating [V]
TC 600 V RMS (Type TC) 600 V RMS (Type TC)
NPLF 150 V RMS (NPLF)

Temperature Range

Operating Temperature Range: -30°C to 90°C Dry, +75°C Wet

Mechanical Characteristics

Bulk Cable Weight: 73 lbs/1000ft
Max. Pull Tension: 97 lbs
Min. Bend Radius/Minor Axis: 1.38 in

Standards

NEC Articles: Article 336
NEC/(UL) Compliance: NPLF, TC-ER, THWN-2 Singles

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes

Suitability

Suitability – Burial: Yes
Suitability – Indoor: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: UL1685 UL Loading
IEEE Flammability: 1202
UL voltage rating: 600 V RMS (Type TC)

Related Part Numbers

Variants
Item # Put-Up Type
A02141O 0105000 Reel

History

Update and Revision: Revision Number: 0.51 Revision Date: 01-10-2024
You were not leaving your cart just like that, right?

You were not leaving your cart just like that, right?

Enter your details below to save your shopping cart for later. And, who knows, maybe we will even send you a sweet discount code :)