Product Overview
| Suitable Applications: |
Internal interconnection, internal wiring of electronic equipment, higher signal density, design flexibility, reliable mass-termination to standard IDC connectors |
Physical Characteristics (Overall)
| AWG |
Stranding |
Material |
| 30 |
7×38 |
TC – Tinned Copper |
| Material |
Nominal Wall Thickness |
| PVC – Polyvinyl Chloride |
0.008 in |
| Table Notes: |
First Conductor has Red Stripe |
Construction and Dimensions
| Conductor Spacing Center-Center: |
.025 +/- .002 in |
| Conductor Spacing Center-Center Outside: |
1.225 +/- .007 in |
| OuterJacket1, Nominal Width: |
1.250 +/- .007 in |
| OuterJacket1, Nom Thick Flat Section: |
0.027 in |
Electrical Characteristics
| Nominal Conductor DCR |
| 108 Ohm/1000ft |
| Element |
Nom. Capacitance Conductor to Conductor |
| @ 1 kHz (GS) |
18 pF/ft |
| @ 1 kHz (GSG) |
32 pF/ft |
| @ 1 MHz (GS) |
14 pF/ft |
| @ 1 MHz (GSG) |
24 pF/ft |
| Min Insulation Resistance: |
10,000 MOhm |
| Element |
Nominal Inductance |
| @ 1 MHz (GS) |
0.21 µH/ft |
| @ 1 MHz (GSG) |
0.14 µH/ft |
| Nominal Balanced Characteristic Impedance Description |
Nominal Characteristic Impedance |
Nominal Characteristic Impedance Description |
| (GS) |
105 Ohm |
(GS) |
| (GSG) |
70 Ohm |
(GSG) |
High Frequency (Nominal/Typical)
| Frequency [MHz] |
Nom. Insertion Loss |
| 10 MHz |
5.4 dB/100ft |
| 20 MHz |
9.5 dB/100ft |
| 30 MHz |
14.1 dB/100ft |
| 40 MHz |
18 dB/100ft |
| 50 MHz |
20.1 dB/100ft |
| 60 MHz |
24.9 dB/100ft |
| 70 MHz |
26.5 dB/100ft |
| 80 MHz |
30 dB/100ft |
| 90 MHz |
30.6 dB/100ft |
| 100 MHz |
33 dB/100ft |
| Table Notes: |
GSG=Ground-Signal-Ground Mode |
| Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
| 1.52 ns/ft |
66% |
| Element |
Typical Unbalanced NEXT % |
Typical Unbalanced FEXT % |
Typical Cross Talk Pulse Rise Time (ns) |
| 10 ft. sample length |
6 |
7.1 |
3 ns |
| 10 ft. sample length |
5.4 |
7 |
5 ns |
| 10 ft. sample length |
5 |
6.6 |
7 ns |
| Max. Recommended Current [A] |
| 0.5 Amps per Conductor at 20ºC |
| Dielectric Withstand Voltage |
UL Voltage Rating |
| 2000 V |
150 V |
Temperature Range
| Operating Temperature Range: |
-40°C to +105°C |
Mechanical Characteristics
| Bulk Cable Weight: |
33 lbs/1000ft |
| Min. Bend Radius/Minor Axis: |
0.5 in |
Standards
| UL AWM Style Compliance: |
AWM 2678 |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2011/65/EU (RoHS 2): |
Yes |
| EU Directive 2012/19/EU (WEEE): |
Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
| EU Directive Compliance: |
Yes |
| CA Prop 65 (CJ for Wire and Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Suitability
| Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
Plenum/Non-Plenum
Related Part Numbers
| Item # |
Color |
Length |
UPC |
| 9L30050 008H100 |
Gray |
100 ft |
612825221777 |
History
| Update and Revision: |
Revision Number: 0.324 Revision Date: 05-05-2023 |