Product Overview
| Suitable Applications: |
Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors, noisy evnvironments |
Physical Characteristics (Overall)
| AWG |
Stranding |
Material |
| 28 |
7×36 |
TC – Tinned Copper |
| Material |
Nominal Wall Thickness |
| PVC – Polyvinyl Chloride |
0.010 in |
| Table Notes: |
First Conductor has Red Stripe |
| Type |
Material |
Material Trade Name |
Coverage [%] |
Drainwire Material |
Drainwire AWG |
Drainwire Construction n x D |
| Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® |
100% |
TC – Tinned Copper |
28 |
7×36 |
| Material |
Nominal Wall Thickness |
| PVC – Polyvinyl Chloride |
0.038 in |
Construction and Dimensions
| Conductor Spacing Center-Center: |
.050 +/- .002 in |
| Conductor Spacing Center-Center Outside: |
1.250 +/- .008 in |
| OuterJacket1, Nominal Width: |
1.370 in |
| OuterJacket1, Nom Thick Flat Section: |
0.115 in |
Electrical Characteristics
| Nominal Conductor DCR |
| 68.2 Ohm/1000ft |
| Element |
Nom. Capacitance Conductor to Conductor |
| @ 1 kHz (GSG) with shield grounded |
70 pF/ft |
| @ 1 MHz (GSG) with shield grounded |
50 pF/ft |
| Min Insulation Resistance: |
10,000 MOhm |
| Element |
Nominal Inductance |
| @ 1 MHz (GSG) with shield grounded |
0.11 µH/ft |
| Nominal Balanced Characteristic Impedance Description |
Nominal Characteristic Impedance |
Nominal Characteristic Impedance Description |
| (GSG) with shield grounded |
45 Ohm |
(GSG) with shield grounded |
High Frequency (Nominal/Typical)
| Frequency [MHz] |
Nom. Insertion Loss |
| 10 MHz |
6 dB/100ft |
| 20 MHz |
9.5 dB/100ft |
| 30 MHz |
12.5 dB/100ft |
| 40 MHz |
14.9 dB/100ft |
| 50 MHz |
17.2 dB/100ft |
| 60 MHz |
19 dB/100ft |
| 70 MHz |
21.5 dB/100ft |
| 80 MHz |
23 dB/100ft |
| 90 MHz |
24.5 dB/100ft |
| 100 MHz |
26 dB/100ft |
| Table Notes: |
GSG=Ground-Signal-Ground Mode |
| Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
| 1.7 ns/ft |
60% |
| Element |
Typical Unbalanced NEXT % |
Typical Unbalanced FEXT % |
Typical Cross Talk Pulse Rise Time (ns) |
| 10 ft. sample length with ground connected to shield |
1.5 |
2 |
3 ns |
| 10 ft. sample length with ground connected to shield |
0.9 |
1.5 |
5 ns |
| 10 ft. sample length with ground connected to shield |
0.7 |
1.2 |
7 ns |
| Max. Recommended Current [A] |
| 1 Amp per Conductor at 20ºC |
| Dielectric Withstand Voltage |
UL Voltage Rating |
| 2000 V |
300 V |
Temperature Range
| Operating Temperature Range: |
-20°C to +105°C |
Mechanical Characteristics
| Bulk Cable Weight: |
97 lbs/1000ft |
| Min. Bend Radius/Minor Axis: |
1.25 in |
Standards
| UL AWM Style Compliance: |
AWM 20081 |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2011/65/EU (RoHS 2): |
Yes |
| EU Directive 2012/19/EU (WEEE): |
Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
| EU Directive Compliance: |
Yes |
| CA Prop 65 (CJ for Wire and Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Suitability
| Suitability – Indoor: |
Yes |
Flammability, LS0H, Toxicity Testing
Plenum/Non-Plenum
Related Part Numbers
| Item # |
Color |
Put-Up Type |
Length |
UPC |
| 9L28326 010100 |
Black |
Reel |
100 ft |
612825221760 |
| Footnote: |
E – MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 25′. |
History
| Update and Revision: |
Revision Number: 0.307 Revision Date: 05-05-2023 |