9L26020 – Flat Gray Ribbon Cable .050″ Pitch, 9L260XX Series, #26-20c, PVC Ins

Call for Price

Description

Product Overview

Suitable Applications: Internal interconnection, internal wiring of electronic equipment, reliable mass-termination to standard IDC connectors

Physical Characteristics (Overall)

Conductor
AWG Stranding Material
26 7×34 TC – Tinned Copper
Conductor Count: 20
Insulation
Material Nominal Wall Thickness
PVC – Polyvinyl Chloride 0.010 in
Color Chart
Color
Gray
Table Notes: First Conductor has Blue Stripe

Construction and Dimensions

Conductor Spacing Center-Center: .050 +/- .002 in
Conductor Spacing Center-Center Outside: .950 +/- .011 in
OuterJacket1, Nominal Width: 1.000 +/- .011 in
OuterJacket1, Nom Thick Flat Section: 0.039 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR
43 Ohm/1000ft
Capacitance
Element Nom. Capacitance Conductor to Conductor
@ 1 kHz (GSG) 23 pF/ft
@ 1 MHz (GS) 11 pF/ft
@ 1 MHz (GSG) 18 pF/ft
Min Insulation Resistance: 10,000 MOhm
Inductance
Element Nominal Inductance
@ 1 MHz (GS) 0.23 µH/ft
@ 1 MHz (GSG) 0.15 µH/ft
Impedance
Nominal Balanced Characteristic Impedance Description Nominal Characteristic Impedance Nominal Characteristic Impedance Description
(GS) 135 Ohm (GS)
(GSG) 90 Ohm (GSG)
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
10 MHz 3.9 dB/100ft
20 MHz 6.4 dB/100ft
30 MHz 8.7 dB/100ft
40 MHz 13 dB/100ft
50 MHz 16.9 dB/100ft
60 MHz 20.1 dB/100ft
70 MHz 22.5 dB/100ft
80 MHz 23.9 dB/100ft
90 MHz 25.1 dB/100ft
100 MHz 26.4 dB/100ft
Table Notes: GS=Ground-Signal Mode; GSG=Ground-Signal-Ground Mode
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.48 ns/ft 68%
Unbalanced Crosstalk
Element Typical Unbalanced NEXT % Typical Unbalanced FEXT % Typical Cross Talk Pulse Rise Time (ns)
10 ft. sample length 5.2 6.2 3 ns
10 ft. sample length 4.2 5 5 ns
10 ft. sample length 3.3 3.8 7 ns
Current
Max. Recommended Current [A]
1.5 Amps per Conductor at 20ºC
Voltage
Dielectric Withstand Voltage UL Voltage Rating
2000 V 300 V

Temperature Range

Operating Temperature Range: -40°C to +105°C

Mechanical Characteristics

Bulk Cable Weight: 33 lbs/1000ft
Min Bend Radius (Overall Cable): 2.2
Min. Bend Radius During Installation: 2.21 in
Min. Bend Radius/Minor Axis: 0.5 in

Standards

UL AWM Style Compliance: AWM 2651
CSA AWM Compliance: I A

Applicable Environmental and Other Programs

EU Directive Compliance: Yes
EU CE Mark: Yes
CA Prop 65 (CJ for Wire and Cable): Yes
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Indoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: VW-1
UL voltage rating: 300 V

Plenum/Non-Plenum

Plenum (Y/N): No

Related Part Numbers

Variants
Item # Color Length UPC
9L26020 008H100 Gray 100 ft 612825221548

History