Product Overview
| Suitable Applications: |
Instrumentation and computer cable; For data transmission applications |
Physical Characteristics (Overall)
| AWG |
Stranding |
Material |
No. of Pairs |
| 24 |
7×32 |
TC – Tinned Copper |
3 |
| Material |
Material Trade Name |
Nominal Diameter |
Diameter +/- Tolerance |
| PE – Polyethylene (Foam) |
Datalene® |
1.55 mm |
0.06 mm |
| Number |
Color |
| Pair 1 |
Black & Red |
| Pair 2 |
Black & White |
| Pair 3 |
Black & Green |
| Table Notes: |
Shielded pairs |
| Number |
Color |
| Pair 1 |
Red |
| Pair 2 |
Green |
| Pair 3 |
Blue |
| Type |
Material |
Material Trade Name |
Thickness of Foil |
Drainwire Material |
Drainwire AWG |
| Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® (Z-Fold®) |
9 / 12 µm |
TC – Tinned Copper |
AWG24/7 |
| Material |
| Bi-Laminate (Alum+Poly) |
| Material |
Nominal Diameter |
Min. Wall Thickness |
Min. Average Wall Thickness |
| LSZH – Low Smoke Zero Halogen (Flame Retardant) |
8.48 mm |
0.91 mm |
1.14 mm |
Construction and Dimensions
| Description |
| 3 pairs twisted to cable core |
| Min Elongation at Breakof Jacket: |
100 % |
| Min Tensile Strength of Jacket: |
10 MPa |
Electrical Characteristics
| Nominal Conductor DCR |
Nominal Inner Shield DCR |
| 78.7 Ohm/km |
49.2 Ohm/km |
| Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
| 41 pF/m |
76.1 pF/m |
| Nominal Pair Inductance |
| 0.75 µH/m |
| Nominal Characteristic Impedance |
| 100 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] |
Nom. Insertion Loss |
| 1 MHz |
3.08 dB/100m |
| 2 MHz |
3.71 dB/100m |
| 3 MHz |
4.43 dB/100m |
| 4 MHz |
5.15 dB/100m |
| 5 MHz |
5.58 dB/100m |
| 12 MHz |
8.43 dB/100m |
| 24 MHz |
11.7 dB/100m |
| Element |
Max. Recommended Current [A] |
| Conductor(s) |
2.5 Amps per Conductor |
Temperature Range
| Installation Temperature Range: |
-15°C To +80°C |
| Storage Temperature Range: |
-20°C To +80°C |
| Operating Temp Range (Fixed Install): |
-15°C To +55°C |
Mechanical Characteristics
| Min. Bend Radius During Installation: |
84.8 mm |
Applicable Environmental and Other Programs
| Environmental Space: |
Indoor |
Flammability, LS0H, Toxicity Testing
| IEC Flammability: |
IEC 60332-3-24 |
| Other Flammability: |
E4156 Part 2 |
| IEC 60754-1 – Halogen Amount: |
Zero |
History
| Update and Revision: |
Revision Number: 0.185 Revision Date: 12-22-2023 |