Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Conductor(s) | 4 | 22 AWG | 7×30 | TC – Tinned Copper |
Insulation
Element | Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
---|---|---|---|---|
Conductor(s) | PP – Polypropylene | 0.011 in (0.28 mm) | 0.050 in (1.3 mm) | Black, White, Red, Green |
Outer Shield
Shield Type | Material |
---|---|
No Shield | No Shield |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) | 0.032 in (0.81 mm) | 0.185 in |
Overall Cable Diameter (Nominal): | 0.185 in |
Electrical Characteristics
Electricals
Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Max. Current |
---|---|---|
17.8 Ohm/1000ft | 15 pF/ft (49 pF/m) | 2.32 Amps per Conductor at 25ºC |
Voltage
UL Voltage Rating |
---|
300 V |
Mechanical Characteristics
Temperature
UL Temperature | Operating |
---|---|
75°C | -20°C To +75°C |
Bend Radius
Stationary Min. | Installation Min. |
---|---|
1.85 in (47.0 mm) | 1.85 in |
Max. Pull Tension: | 36.4 lbs (16.5 kg) |
Bulk Cable Weight: | 20 lbs/1000ft |
Standards and Compliance
Environmental Suitability: | Indoor, Non-Halogenated |
Flammability / Reaction to Fire: | UL 1685 FT4 Loading, FT4 |
NEC / UL Compliance: | Article 800, CMG |
AWM Compliance: | AWM 21307 |
CEC / C(UL) Compliance: | CMG |
European Directive Compliance: | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
History
Update and Revision: | Revision Number: 0.286 Revision Date: 05-05-2023 |
Part Numbers
Variants
Item # | Color | UPC |
---|---|---|
8444ZH 0101000 | Black | 612825382256 |
8444ZH 010500 | Black | 612825382263 |