Description
Product Overview
| Suitable Applications: | Analog Video; Interconnect camera to CCU (camera control unit) |
Construction Details
| RG Type: | 11 |
Conductor
| Size | Stranding | Nom. Diameter | Material |
|---|---|---|---|
| 14 AWG | Solid | 0.064 in | BC – Bare Copper |
Insulation
| Material | Nom. Insulation Diameter | Color Code |
|---|---|---|
| FEP – Fluorinated Ethylene Propylene (Foam) | 0.285 in (7.24 mm) | White |
Inner Shield
| Layer | Shield Type | Material | Coverage |
|---|---|---|---|
| 1 | Braid | Bare Copper (BC) | 95% |
Inner Jacket
| Material | Nom. Diameter |
|---|---|
| PVDF – Polyvinylidene Fluoride | 0.350 in (8.89 mm) |
Outer Shield
| Layer | Outer Shield Type | Material | Coverage |
|---|---|---|---|
| 1 | Braid | Bare Copper (BC) | 80% |
Outer Jacket
| Material | Nom. Diameter |
|---|---|
| PVDF – Polyvinylidene Fluoride | 0.408 in (10.4 mm) |
| Overall Cable Diameter (Nominal): | 0.408 in (10.4 mm) |
Electrical Characteristics
Return Loss (RL)
| Frequency | Min. Return Loss |
|---|---|
| 5 – 850 MHz | 21 dB |
| 850 – 4500 MHz | 15 dB |
Attenuation
| Frequency | Nom. Attenuation |
|---|---|
| 1 MHz | 0.09 dB/100ft |
| 3.6 MHz | 0.28 dB/100ft |
| 10 MHz | 0.47 dB/100ft |
| 71.5 MHz | 1.33 dB/100ft |
| 135 MHz | 1.90 |
| 270 MHz | 2.94 dB/100ft |
| 360 MHz | 3.42 dB/100ft |
| 540 MHz | 4.46 dB/100ft |
| 720 MHz | 5.41 dB/100ft |
| 750 MHz | 5.51 dB/100ft |
| 1000 MHz | 6.74 dB/100ft |
| 1500 MHz | 9.03 dB/100ft |
| 2250 MHz | 11.30 dB/100ft |
| 3000 MHz | 12.54 dB/100ft |
| 3000 MHz | 17.00 dB/100ft |
| 4000 MHz | 27.45 dB/100ft |
Electricals
| Nom. Conductor DCR | Nom. Inner Shield DCR | Nom. Outer Shield DCR | Nom. Capacitance Cond-to-Shield |
Nom. Characteristic Impedance | Nom. Velocity of Prop. |
|---|---|---|---|---|---|
| 2.5 Ohm/1000ft | 1.6 Ohm/1000ft (5.2 Ohm/km) | 1.4 Ohm/1000ft (4.6 Ohm/km) | 16.5 pF/ft (54.1 pF/m) | 75 Ohm | 80% |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 125°C | -15°C to +125°C |
Bend Radius
| Installation Min. |
|---|
| 4.0 in (100 mm) |
| Max. Pull Tension: | 170 lbs (77 kg) |
| Bulk Cable Weight: | 132 lbs/1000ft |
Standards and Compliance
| Environmental Suitability: | Indoor – Plenum, Indoor |
| Sustainability: | CA Prop 65 |
| Flammability / Reaction to Fire: | NFPA 262 |
| NEC / UL Compliance: | CMP |
| CEC / C(UL) Compliance: | CMP |
| European Directive Compliance: | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance: | China RoHS II (GB/T 26572-2011) |
| Non-Plenum Number: | 8233A |
History
| Update and Revision: | Revision Number: 0.449 Revision Date: 11-27-2023 |
Part Numbers
Variants
| Item # | Color | Putup Type | Length | UPC |
|---|---|---|---|---|
| 8233P 010500 | Black | Reel | 500 ft | 612825440031 |
| 8233P 0101000 | Black | Reel | 1,000 ft | 612825196662 |
| 8233P 0105000 | Black | Reel | 5,000 ft | 612825354970 |