Physical Characteristics (Overall)
| AWG |
Stranding |
Material |
Nominal Diameter |
No. of Coax |
| 20 |
Solid |
BC – Bare Copper |
0.032 in |
1 |
| Material |
Nominal Diameter |
| PE – Polyethylene (Foam) |
0.145 in |
| Table Notes: |
Gas Injected |
| Type |
Material |
Coverage [%] |
| Braid |
Bare Copper (BC) |
95% |
| Material |
Nominal Diameter |
| PVC – Polyvinyl Chloride |
0.225 in |
| Type |
Material |
Coverage [%] |
| Braid |
Bare Copper (BC) |
80% |
| Material |
Nominal Diameter |
| PVC – Polyvinyl Chloride |
0.315 in |
Electrical Characteristics
| Nominal Conductor DCR |
Nominal Conductor DCR Conductor Resistance |
Nominal Inner Shield DCR |
Nominal Outer Shield DCR |
| 10 Ohm/1000ft |
10 Ohm/1000ft |
2.5 Ohm/1000ft |
2.8 Ohm/1000ft |
| Nom. Capacitance Conductor to Shield |
| 16.2 pF/ft |
| Nominal Inductance |
| 0.097 µH/ft |
| Nominal Characteristic Impedance |
| 75 Ohm |
| Frequency [MHz] |
Min. Structural Return Loss (SRL) |
| 5-850 MHz |
21 dB |
| 850-4500 MHz |
15 dB |
High Frequency (Nominal/Typical)
| Frequency [MHz] |
Nom. Insertion Loss |
| 1 MHz |
0.3 dB/100ft |
| 3.6 MHz |
0.6 dB/100ft |
| 10 MHz |
0.9 dB/100ft |
| 71.5 MHz |
2.1 dB/100ft |
| 135 MHz |
3 dB/100ft |
| 270 MHz |
4.2 dB/100ft |
| 360 MHz |
4.8 dB/100ft |
| 540 MHz |
5.9 dB/100ft |
| 720 MHz |
7 dB/100ft |
| 750 MHz |
7.1 dB/100ft |
| 1000 MHz |
8.3 dB/100ft |
| 1500 MHz |
10.5 dB/100ft |
| 2250 MHz |
13.4 dB/100ft |
| 3000 MHz |
15.9 dB/100ft |
| Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
| 1.22 ns/ft |
83% |
| Frequency [MHz] |
Max. Insertion Loss (Attenuation) |
| 400 MHz |
6.9 dB/100ft |
| UL Voltage Rating |
| 300 V RMS |
Temperature Range
| Operating Temperature Range: |
-40°C To +75°C |
Mechanical Characteristics
| Bulk Cable Weight: |
63 lbs/1000ft |
| Max. Pull Tension: |
125 lbs |
| Min. Bend Radius/Minor Axis: |
3.25 in |
Standards
| CEC/C(UL) Compliance: |
CMG |
Applicable Environmental and Other Programs
| Environmental Space: |
Indoor/Outdoor |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2011/65/EU (RoHS 2): |
Yes |
| EU Directive 2012/19/EU (WEEE): |
Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment): |
Yes |
| EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
| MII Order #39 (China RoHS): |
Yes |
Suitability
| Suitability – Aerial: |
Yes – When supported by messenger wire |
| Suitability – Indoor: |
Yes |
| Suitability – Outdoor: |
Yes |
Flammability, LS0H, Toxicity Testing
| UL Flammability: |
UL1666 Vertical Shaft |
| UL voltage rating: |
300 V RMS |
Plenum/Non-Plenum
Related Part Numbers
| Item # |
Color |
Put-Up Type |
Length |
UPC |
| 8232A 0101000 |
Black |
Reel |
1,000 ft |
612825438267 |
| 8232A 0102500 |
Black |
Reel |
2,500 ft |
612825355588 |
| Footnote: |
C – CRATE REEL PUT-UP. |
History
| Update and Revision: |