Product Overview
Suitable Applications: |
Instrumentation and computer cable; For data transmission applications |
Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Pairs |
24 |
7×32 |
TC – Tinned Copper |
10 |
Material |
Material Trade Name |
Nominal Diameter |
Diameter +/- Tolerance |
PE – Polyethylene (Foam) |
Datalene® |
1.24 mm |
0.06 mm |
Number |
Color |
Pair 1 |
White/Blue & Blue/White |
Pair 2 |
White/Orange & Orange/White |
Pair 3 |
White/Green & Green/White |
Pair 4 |
White/Brown & Brown/White |
Pair 5 |
White/Gray & Gray/White |
Pair 6 |
Red/Blue & Blue/Red |
Pair 7 |
Red/Orange & Orange/Red |
Pair 8 |
Red/Green & Green/Red |
Pair 9 |
Red/Brown & Brown/Red |
Pair 10 |
Red/Gray & Gray/Red |
Type |
Material |
Material Trade Name |
Thickness of Foil |
Drainwire Material |
Drainwire AWG |
Min. Coverage [%] |
Tape |
Bi-Laminate (Alum+Poly) |
Beldfoil® (Z-Fold®) |
9 / 12 µm |
TC – Tinned Copper |
AWG24/7 |
|
Braid |
Tinned Copper (TC) |
|
|
|
|
65% |
Material |
Nominal Diameter |
Min. Wall Thickness |
Min. Average Wall Thickness |
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
10.29 mm |
0.7 mm |
0.813 mm |
Construction and Dimensions
Description |
Filler |
2 fillers and 10 pairs twisted to cable core |
Polypropylene (2x) |
Electrical Characteristics
Nominal Conductor DCR |
Nominal Outer Shield DCR |
78.7 Ohm/km |
8.5 Ohm/km |
Max. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Conductor |
Nom. Capacitance Conductor to Other Conductor to Shield |
45.9 pF/m |
41 pF/m |
72.2 pF/m |
Nominal Pair Inductance |
0.75 µH/m |
Nominal Characteristic Impedance |
100 Ohm |
Nominal Velocity of Propagation (VP) [%] |
78% |
Element |
Max. Recommended Current [A] |
Conductor(s) |
1.5 Amps per Conductor |
Temperature Range
Storage Temperature Range: |
-45°C To +80°C |
Operating Temp Range (Fixed Install): |
-45°C To +80°C |
Mechanical Characteristics
Min. Bend Radius During Installation: |
102.9 mm |
Min Setting Radius: |
51.45 mm |
Standards
CENELEC Compliance: |
EN 50290-2-20 |
Applicable Environmental and Other Programs
Environmental Space: |
Indoor |
Flammability, LS0H, Toxicity Testing
IEC Flammability: |
IEC 60332-3-24 |
IEC 60754-1 – Halogen Amount: |
Zero |
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity: |
2.5 µS/mm |
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH: |
4.3 |
IEC 61034-2 – Smoke Density Min. Transmittance: |
60% |
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
EAN |
8110NH.00152 |
Chrome |
Reel |
152 m |
8719605017895 |
8110NH.00305 |
Chrome |
Reel |
305 m |
8719605017901 |
8110NH.00500 |
Chrome |
Reel |
500 m |
8719605017918 |
History
Update and Revision: |
Revision Number: 0.249 Revision Date: 12-22-2023 |