Product Overview
Suitable Applications: | Long distance sensors in harsh environment at Industrial edge, 1 single pair Ethernet up to 20 MHz |
Construction Details
Conductor
Size | Stranding | Material |
---|---|---|
22 AWG | 7×0.25 mm | TC – Tinned Copper |
Insulation
Material | Nom. Insulation Diameter | Color Code |
---|---|---|
PE – Polyethylene (Foam) | 1.65 mm (0.0650 in) | White, Blue |
Outer Shield
Shield Type | Material | Coverage | Notes |
---|---|---|---|
Tape | Polyester | 100% | |
Tape | Bi-Laminate (Alum+Poly) | 100% | |
Braid | Tinned Copper (TC) | 80% | 23 AWG Stranded Drain wire along with shielding |
Outer Jacket
Material |
---|
LSZH – Low Smoke Zero Halogen (Flame Retardant) |
Overall Cable Diameter (Nominal): | 5.3 mm (0.21 in) |
Electrical Characteristics
Electricals
Max. Conductor DCR | Max. Capacitance Unbalance | Nom. Characteristic Impedance |
---|---|---|
59.4 Ohm/km at 20°C | 160 pF/100m | 100 Ohm |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] | Max. Surface Transfer Impedance | Nom. Characteristic Impedance [Ohm] |
---|---|---|---|---|---|---|
0.1 | 1.5 | 15 | 50 | 55 | ||
1 | 2.2 | 20 | 40 | 35 | 50 | |
4 | 3.9 | 23 | 31 | 23 | 75.9 | |
10 | 6.1 | 25 | 25 | 15 | 100 | |
20 | 8.6 | 25 | 20.5 | 9 | 154.9 | |
100 |
Voltage
UL Voltage Rating | Breakdown Voltage |
---|---|
300 V | 2 Kvac/min. |
Mechanical Characteristics
Temperature
Operating |
---|
-20°C To +80°C |
Standards and Compliance
Flammability / Reaction to Fire: | FT2 |
AWM Compliance: | AWM 21307 |
ISO/IEC Compliance: | IEC 61156-xx, UL 758 |
APAC Compliance: | China RoHS II (GB/T 26572-2011) |
Product Notes
Notes: | Flame Test: EN50575 Dca-s2,d2,a2 |
History
Update and Revision: | Revision Number: 0.4 Revision Date: 03-15-2024 |