3095A – ControlBus™, Coax RG11, #14 Sol BCCS, FEP Ins, QUAD AL Shld, PVDF Jkt, CMP

Call for Price

Description

Product Overview

Suitable Applications: harsh environment, factory automation, ControlNet™, Modbus II, Industrial Coax, Belden ControlNet cables provide maximum signal integrity and run length exceeding the high-speed, time-critical requirements necessary for ControlNet factory floor applications

Physical Characteristics (Overall)

Conductor
AWG Stranding Material Nominal Diameter No. of Coax
14 Solid BCCS – Bare Copper Covered Steel 0.064 in 1
Conductor Count: 1
Insulation
Material Nominal Diameter
FEP – Fluorinated Ethylene Propylene (Foam) 0.28 in
Outer Shield
Type Layer Material Material Trade Name Coverage [%]
Tape 1 Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
Braid 2 Aluminum 60%
Tape 3 Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
Braid 4 Aluminum 40%
Outer Jacket
Material Nominal Diameter
PVDF – Polyvinylidene Fluoride 0.387 in

Electrical Characteristics

Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR Outer Conductor DCR
11 Ohm/1000ft 3.9 Ohm/1000ft 3.9 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Shield
16.5 pF/ft
Inductance
Nominal Inductance
0.097 µH/ft
Impedance
Nominal Characteristic Impedance Nominal Characteristic Tolerance
100 Ohm ± 3 Ohm
High Frequency (Nominal/Typical)
Frequency [MHz] Nom. Insertion Loss
1 MHz 0.17 dB/100ft
2 MHz 0.22 dB/100ft
5 MHz 0.28 dB/100ft
10 MHz 0.4 dB/100ft
20 MHz 0.6 dB/100ft
50 MHz 1.2 dB/100ft
100 MHz 1.7 dB/100ft
200 MHz 2.5 dB/100ft
300 MHz 3.04 dB/100ft
400 MHz 3.5 dB/100ft
Delay
Nominal Delay Nominal Velocity of Propagation (VP) [%]
1.2 ns/ft 82%
Phase Delay Distortion
f/B %PDD/100M (5MB)
0.5 -0.6
1 -0.46
1.5 0
2 0.17
2.5 0.3
High Frequency
Frequency [MHz] Min. SRL (Structural Return Loss)
1 MHz 20 dB
2 MHz
5 MHz
10 MHz
20 MHz
50 MHz
100 MHz
200 MHz
300 MHz
400 MHz
Voltage
UL Voltage Rating
300 V RMS
Electrical Characteristics Notes: Tilt 5 to 10 MHz: .42 dB/100 M
Other Electrical Characteristic 2: Tilt 10 to 20 MHz: .58 dB/100 M
Other Electrical Characteristic 3: SLR Min. 20dB (5MHz – 50MHz)

Temperature Range

UL Temp Rating: 150°C
Operating Temperature Range: -20°C To +150°C

Mechanical Characteristics

Bulk Cable Weight: 68 lbs/1000ft
Max. Pull Tension: 309 lbs
Min. Bend Radius/Minor Axis: 4 in

Standards

NEC Articles: Article 800
NEC/(UL) Compliance: CMP
CEC/C(UL) Compliance: CMP
RG Type: 11

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHS): Yes

Suitability

Suitability – Burial: Yes
Suitability – Outdoor: Yes

Flammability, LS0H, Toxicity Testing

UL Flammability: NFPA 262
CSA Flammability: FT6
UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): Yes

Related Part Numbers

Non-Plenum Number: 3094A

Product Notes

Notes: Sweep tested 5 to 400 MHz. Tap marks every 2.6 meters to aid users in installation.

History

Update and Revision: Revision Number: 0.304 Revision Date: 11-16-2023