127919A – DataTuff® 5e, 4 Pr #24 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt, CM CSA CMG HL -40C

Call for Price

Compare

Description

Product Overview

Suitable Applications: mining, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc. exposure to rodent, crush, or cut through force,

Physical Characteristics (Overall)

Conductor
Element AWG Stranding Material No. of Pairs
Pair(s) 24 Solid BC – Bare Copper 4
Insulation
Material
PO – Polyolefin
Bonded-Pair: No
Color Chart
Color
White/Blue Stripe & Blue
White/Orange Stripe & Orange
White/Green Stripe & Green
White/Brown Stripe & Brown
Inner Jacket
Material Nominal Diameter Ripcord
PVC – Polyvinyl Chloride 0.265 in Yes
Outer Shield
Type Material Material Trade Name Coverage [%]
Tape Polyester + Bi-Laminate (Alum+Poly) Beldfoil® 100%
Outer Jacket
Material Nominal Diameter Ripcord Separator Material
PVC – Polyvinyl Chloride 0.615 in No Polyester Tape

Construction and Dimensions

Armor
Diameter over Armoring
0.525 in

Electrical Characteristics

Conductor DCR
Max. Conductor DCR
93.8 Ohm/km
Capacitance
Max. Capacitance Unbalance
330 pF/100m
Delay
Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
538 ns/100m 45 ns/100m 70%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Min. SRL (Structural Return Loss) Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance
1 MHz 2.0 dB/100m 65.3 dB 62.3 dB 63.3 dB 60 dB 63.8 dB 60.8 dB 20 dB 23 dB 100 ± 15 Ohm 102.5 ± 7.5 Ohm
4 MHz 4.1 dB/100m 56.3 dB 53.3 dB 51 dB 49 dB 51.7 dB 48.7 dB 23.6 dB 23 dB 100 ± 15 Ohm 102.5 ± 7.5 Ohm
8 MHz 5.8 dB/100m 51.8 dB 48.8 dB 46 dB 43 dB 45.7 dB 42.7 dB 25.4 dB 24.5 dB 100 ± 15 Ohm 101 ± 6 Ohm
10 MHz 6.5 dB/100m 50.3 dB 47.3 dB 43 dB 41 dB 43.8 dB 40.8 dB 26 dB 25 dB 100 ± 15 Ohm 101 ± 6 Ohm
16 MHz 8.2 dB/100m 47.3 dB 44.3 dB 39 dB 36 dB 39.7 dB 36.7 dB 26 dB 25 dB 100 ± 15 Ohm 101 ± 6 Ohm
20 MHz 9.3 dB/100m 45.8 dB 42.8 dB 36.5 dB 33.5 dB 37.7 dB 34.7 dB 26 dB 25 dB 100 ± 15 Ohm 101 ± 6 Ohm
25 MHz 10.4 dB/100m 44.3 dB 41.3 dB 33.9 dB 30.9 dB 35.8 dB 32.8 dB 25.5 dB 24.3 dB 100 ± 15 Ohm 101 ± 6 Ohm
31.25 MHz 11.7 dB/100m 42.9 dB 39.9 dB 31 dB 28 dB 33.9 dB 30.9 dB 25 dB 23.6 dB 100 ± 15 Ohm 101 ± 6 Ohm
62.5 MHz 17.0 dB/100m 38.4 dB 35.4 dB 22 dB 19 dB 27.8 dB 24.8 dB 23.5 dB 21.5 dB 100 ± 15 Ohm 101 ± 6 Ohm
100 MHz 22.0 dB/100m 35.3 dB 32.3 dB 14 dB 11 dB 23.8 dB 20.8 dB 22.5 dB 20.1 dB 100 ± 15 Ohm
Current
Max. Recommended Current [A]
15 pF/ft
Voltage
UL Description UL Voltage Rating
CM 300 V

Temperature Range

UL Temp Rating: 75°C
Storage Temperature Range: -40°C to +85°C
Operating Temperature Range: -40°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 130 lbs/1000ft
Max. Pull Tension: 100 lbs

Standards

NEC Articles: Article 800
NEC/(UL) Compliance: CM
CEC/C(UL) Compliance: CMG, HL
CPR Euroclass: Eca
Data Category: Category 5e
TIA/EIA Compliance: ANSI/TIA-568.2-D Category 5e

Applicable Environmental and Other Programs

Environmental Space: Indoor/Outdoor

Suitability

Suitability – Aerial: No
Suitability – Burial: No
Suitability – Indoor: Yes
Suitability – Non-Halogenated: No
Suitability – Oil Resistance: Yes
Suitability – Outdoor: Yes
Suitability – Sunlight Resistance: Yes

Flammability, LS0H, Toxicity Testing

CSA/C(UL) Flammability: FT4
UL Flammability: UL 1685 (UL Loading)

Product Notes

Notes: Operating temperatures are subject to length de-rating

History