Description
Product Overview
Suitable Applications: | exposure to rodent, crush, or cut through force, harsh environment, outdoors, data transmission applications such as Profibus DP or PA, Instrumentation and computer cable, etc. exposure to temperature extremes, humidity/moisture, dust, and oil. |
Construction Details
Conductor
Element | No. of Elements | Size | Stranding | Material |
---|---|---|---|---|
Pair(s) | 1 | 22 AWG | 7×30 | BC – Bare Copper |
Insulation
Element | Material | Nom. Thickness | Color Code | Notes |
---|---|---|---|---|
Pair(s) | PE – Polyethylene (Foam) | 0.035 in (0.89 mm) | Red & Green | Flame Retardant, Foam w/ skin |
Outer Shield
Shield Type | Material | Coverage |
---|---|---|
Tape | Bi-Laminate (Alum+Poly) | 100% |
Braid | Tinned Copper (TC) | 65% |
Inner Jacket
Material | Nom. Diameter |
---|---|
PVC – Polyvinyl Chloride | 0.314 in (7.98 mm) |
Armor
Armor Type & Material |
---|
AIA – Aluminum Interlock Armor |
Outer Jacket
Material | Nom. Thickness | Nom. Diameter |
---|---|---|
PVC – Polyvinyl Chloride | 0.045 in (1.1 mm) | 0.608 in (15.4 mm) |
Overall Cable Diameter (Nominal): | 0.608 in (15.4 mm) |
Electrical Characteristics
Electricals
Element | Nom. Characteristic Impedence | Nom. Velocity of Prop. |
---|---|---|
Pair(s) | 150 Ohm | 78% |
High Frequency (Nominal/Typical)
Element |
---|
Pair(s) |
Voltage
UL Voltage Rating |
---|
300 V (CM, PLTC) |
Standards and Compliance
Environmental Suitability: | Outdoor, Sunlight Resistance |
NEC / UL Compliance: | Article 725, Article 800, CM, PLTC |
CEC / C(UL) Compliance: | CM |
History
Update and Revision: | Revision Number: 0.60 Revision Date: 02-15-2024 |