26523 – ACIC 300V, 2 Tri #18 Str TC, PVC Ins E1, IS/OS, PVC Jkt, SIA Armor, PVC Jkt, 105C Dry 75C Wet CSA HLBCD SUN RES -40C

Call for Price

Description

Product Overview

Suitable Applications: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners

Construction Details

Conductor
Element No. of Elements Size Stranding Material
Conductor(s) 3 18 AWG 7×26 TC – Tinned Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Conductor(s) PVC – Polyvinyl Chloride 0.025 in (0.64 mm) 0.096 in (2.4 mm) Red, Black, White
Inner Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 20 AWG (7×28) TC
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 18 AWG (7×26) TC
Inner Jacket
Separator Material Nom. Thickness Nom. Diameter Ripcord
Polyester Tape PVC – Polyvinyl Chloride 0.047 in (1.2 mm) 0.507 in (12.9 mm) Yes
Armor
Armor Type & Material Armor Thickness Armor Material Diameter
SIA – Steel Interlock Armor 0.025 in (0.64 mm) 0.727 in (18.5 mm)
Outer Jacket
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.052 in (1.3 mm) 0.831 in (21.1 mm)
Overall Cable Diameter (Nominal): 0.831 in (21.1 mm)

Electrical Characteristics

Electricals
Element Nom. Conductor DCR Nom. Inner Shield DCR Max. Current
Triad(s) 7.4 Ohm/1000ft 7.06 Ohm/km (2.15 Ohm/1000ft) 9.1 Amps per Conductor at 30ºC
Voltage
Voltage Rating
300 V (ACIC)

Mechanical Characteristics

Temperature
Operating
-40°C To +75°C Wet, -40°C To +105°C Dry
Bend Radius
Stationary Min. Installation Min.
9.97 in (253 mm) 9.97 in (253 mm)
Max. Pull Tension: 369.4 lbs (167.6 kg)
Bulk Cable Weight: 452 lbs/1000ft

Standards and Compliance

Environmental Suitability: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, UV Resistance
CEC / C(UL) Compliance: HL, ACIC

History

Update and Revision: Revision Number: 0.97 Revision Date: 01-10-2024