Physical Characteristics (Overall)
AWG |
Stranding |
Material |
No. of Conductors |
18 |
41×34 |
BC – Bare Copper |
2 |
Material |
Nominal Wall Thickness |
CPE – Chlorinated Polyethylene |
0.047 in |
Nominal Diameter |
0.14 x 0.276 in |
Construction and Dimensions
Electrical Characteristics
Max. Recommended Current [A] |
10 Amps per Conductor at 25ºC (7 Amps over 50 ft) |
7 Amps per Conductor at 25ºC (over 50 ft) |
Dielectric Withstand Voltage |
UL Voltage Rating |
1500 V AC Applied for 1 Min. |
300 V RMS |
Electrical Characteristics Notes: |
Dielectric Withstand Voltage: 1500 V AC Applied for 1 Min |
Temperature Range
Operating Temperature Range: |
-30°C To +90 |
Mechanical Characteristics
Bulk Cable Weight: |
28 lbs/1000ft |
Min. Bend Radius/Minor Axis: |
1.5 in |
Standards
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2003/96/EC (BFR): |
Yes |
EU Directive 2011/65/EU (RoHS 2): |
Yes |
EU Directive 2012/19/EU (WEEE): |
Yes |
EU Directive Compliance: |
EU Directive 2003/11/EC (BFR) |
MII Order #39 (China RoHS): |
Yes |
Flammability, LS0H, Toxicity Testing
UL voltage rating: |
300 V RMS |
Plenum/Non-Plenum
Related Part Numbers
Item # |
Color |
Put-Up Type |
Length |
UPC |
19405 010250 |
Black |
Reel |
250 ft |
612825127079 |
19405 0101000 |
Black |
Reel |
1,000 ft |
612825127062 |
Footnote: |
C – CRATE REEL PUT-UP., F – MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 50′. |
History
Update and Revision: |
Revision Number: 0.385 Revision Date: 05-05-2023 |